• HUATEC GROUP CORPORATION
    باب
    Astm E114-15 Inch Type 1018 Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    ویلیام
    Astm E114-15 Inch Type 1018 Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    تام
    Astm E114-15 Inch Type 1018 Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    لئو
    Astm E114-15 Inch Type 1018 Test Block Carbon Steel Mini Iiw 2
تماس با شخص : Noah
شماره تلفن : +8613911115555
واتساپ : +8613910983110

Mini 250KV X-Ray Flaw Detector Ceramic Tube Penetrant 40mm Directional Radiographic Inspection Machine

محل منبع پکن
نام تجاری HUATEC
گواهی ISO, CE, GOST
شماره مدل XXG-2505
مقدار حداقل تعداد سفارش 1PCS
جزئیات بسته بندی بسته بندی استاندارد تخته سه لا صادراتی
زمان تحویل 1-4 روز
شرایط پرداخت T/T، Paypal، وسترین یونیون
قابلیت ارائه 500 عدد در ماه

برای نمونه ها و کوپن های رایگان با من تماس بگیرید.

واتساپ:0086 18588475571

وی چت: 0086 18588475571

اسکایپ: sales10@aixton.com

اگر شما هر گونه نگرانی دارید، ما 24 ساعت کمک آنلاین ارائه می دهیم.

x
جزئیات محصول
خروجی 100-250 کیلو ولت ورودی 2.5 کیلو وات
نقطه تمرکز 2.0X2.0 حداکثر نفوذ 40 میلی متر
مواد فولاد زاویه تابش 40±5 درجه
استفاده تست اشعه ایکس صنعتی، تست جوش، دستگاه تست اشعه ایکس صنعتی منبع برق AC220 ± 10٪، 50 هرتز
درخواست آزمایش اشعه ایکس صنعتی، تشخیص درز جوش تضمین 12 ماه
مدت زمان قرارگیری در معرض بیماری 5 دقیقه اندازه کنترل کننده 350*290*170 میلی متر
اندازه ژنراتور 270×270×615 وزن ژنراتور ۲۱ کیلوگرم
برجسته کردن

welding x ray machine,industrial x ray machine

,

industrial x ray machine

پیام بگذارید
توضیحات محصول

250KV Ceramic tube penetrant 40mm Directional Radiographic inspection machine
 
Mini 250KV X-Ray Flaw Detector Ceramic Tube Penetrant 40mm Directional Radiographic Inspection Machine 0
 
Units of Keyboard

0-9 as digital keys for presetting time and kv value.

Voltage status key(U):Press the key,status bit shows"U" ,the operator can input 3-digital Voltage value.

Time status key(H):Press the key,status bit shows "H" , the operator can input 2-digital time value.

Delay status(A):Press the key,status bit shows "A" , the operator can input 2-digital delay time.

"AG" key:Manual aging key,the unit will begin to age from min.kv value to the max with fixed 7.5 min of time interruption.

"ON" key:Turn on high voltage,it is effective in all status so long as the operator input correct parameters.

"OFF" key:Turn off high voltage when high voltage is turned on or it is in aging state; Clear protection indicator after the trouble clearing.
 
Mini 250KV X-Ray Flaw Detector Ceramic Tube Penetrant 40mm Directional Radiographic Inspection Machine 1
 
Main Features:
◆ A unique safety lock is designed that protect the operator from the damage of radiation.
◆ Adopting the wider range of KV value, and solve the difficulty problem of short radiographic range.

◆ Exposure delay function ------the delay time can be set less than 10 minutes to keep the operator safe from working place.
◆ Match with various generator and function reliably.
◆ Number of exposure can be accumulated.
(After the unit has been ready, but before press the "ON" key, you can press the "A" key (delay key) three times to check the number of exposure, and press any key to return back.)
◆ With the outlet of ray warning lamp and wire connecting terminal of door-machine interlock.

(Door-machine interlock—when the lead door opens, the instrument cut off the high voltage automatically to protect the operator)
◆ Adopting micro-computer control and modular structure, with strong anti-interference ability and high automaticity and reliable performance.
◆ Parameter setting, working process and trouble indication will be indicated on the LED screen.
◆ Independent aging key is designed for aging the machine conveniently.
◆ Radiating time to cooling time is 1:1.
◆ The controller can recognize the type of x-ray generator automatically.
◆ The water and dust proof color panel and digital sound keyboard are introduced that exposure parameters are promptly and accurately selected.
◆ Ensure safety using the instrument, it is installed with overvoltage, under voltage,
over current, under current and over temperature protection device.
XXG2505 Ceramic tube orientation/directional Main technical parameters
 

TYPE 

Mini XXG2505
Max Penetration thickness Steel (A3) 40mm 5minutes
Focal Distance 600mm
Exposure Time 5min
Film Type Agfa D7

Double lead foil Intensifying screen

0.03
Darkroom Disposal 20±2℃
Development 5minutes
Blackness 1.5
Input Voltage (V) 220V±10% 50―60Hz
Capacity (KVA) 2.0
Output Tube voltage (KVP) 100-250
Tube current (mA) 5
Stability ±1%

X-RAY
Tube

Focus mm2 2.0×2.0
Radiation Angle 40±5°
Sensitivity k≤1.8%
Operation Mode Intermittent operation, Radiating time to cooling time is 1:1

X-Ray
Controller

Dimension 270×270×140
Weight 9kg
Circuit Structure Micro-computer control ,Modular structure,Voice prompt

X-RAY
Generator

Cooling Force air cooling
Insulation SF6 Gas Insulation
Working Pressure 0.35Mpa-0.45Mpa
Dimension 270×270×615
Weight (kg) 21kg
Working Temperature -10℃―+40℃

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Usage:
The HUATEC Flaw detector products have been widely used for nondestructive testing in spaceflight industry, welding engineering industry, shipbuilding industry, boiler pipe industry, petrochemical engineering industry, aircraft manufacturing, maintenance industry, automotive industry, defense industries, etc.
Standard Delivery

Directional glass X-ray tube 1 Pcs  
Generator 1 Set  
High voltage joins cable 1 Pcs 25 Meters
Controller 1 Set  
Power cable 1 Pcs 10 Meters
Grounding cable 1 Pcs 5 Meters
Accessories 1 Set  
(Including: alarm lamp,1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc)


 Mini 250KV X-Ray Flaw Detector Ceramic Tube Penetrant 40mm Directional Radiographic Inspection Machine 2